OM-1308 Page 16
4-10. Troubleshooting
Trouble Remedy
No weld output; wire does not feed. Be sure line disconnect switch is On (see Section 2-11).
Replace building line fuse or reset circuit breaker if open (see Section 2-11).
Reset circuit breaker CB1 (see Section 4-2).
Secure gun trigger connections (see Section 2-5).
Check and replace Power switch if necessary.
Have Factory Authorized Service Agent check all board connections and main control board.
No weld output; wire feeds. Thermostat TP1 open (overheating). Allow fan to run; the thermostat will close when the unit has cooled
(see Section 2-2).
Connect work clamp to get good metal to metal contact.
Replace contact tip (see Section 4-4).
An overload condition occurred. Release gun trigger (see Section 4-3).
Have Factory Authorized Service Agent check main control board and main rectifier.
Low weld output. Connect unit to proper input voltage or check for low line voltage (see Section 2-11).
Check input voltage jumper links and correct position if necessary (see Section 2-9).
Have Factory Authorized Service Agent check main control board.
Fan motor does not run.
NOTE: Fan only runs when cooling
is necessary.
Have Factory Authorized Service Agent check fan-on-demand circuit.
Low, high, or erratic wire speed. Readjust front panel settings (see Section 3-1).
Place Low Range/Full Range switch in correct position (see Section 3-1).
Change to correct size drive rolls (see Section 4-5).
Readjust drive roll pressure (see Section 2-12).
Replace inlet guide, contact tip, and/or liner if necessary (see Sections 4-4, and 4-8).
Check position of input jumper links (see Section 2-9).
Have Factory Authorized Service Agent check main control board.
No wire feed. Reset circuit breaker CB1 (see Section 4-2).
Turn Wire Speed control to higher setting (see Section 3-1).
Clear obstruction in gun contact tip or liner (see Sections 4-4 and 4-8).
Readjust drive roll pressure (see Section 2-12).
Change to correct size drive rolls (see Section 4-5).
Rethread welding wire (see Section 2-12).
Check gun trigger and leads. Repair or replace gun if necessary.
Have Factory Authorized Service Agent check main control board.
Poor weld bead, or welding
wire is noodle welding.
Check polarity setting for type of welding wire being used (see Section 2-6).
Vue de la page 19