®Auto-Darkening HelmetsModel: Powered Air-PurifyingRespirator (PAPR)OM-235 936C2011−02To help us serve you better, go to www.MillerWelds.Com/HelmetReg
POWERED AIR PURIFYING RESPIRATOROM-235 936 Page 82-3. Installing The Battery1 Battery2 Battery Unlock ButtonSlide battery into blower body untilbatter
POWERED AIR PURIFYING RESPIRATOROM-235 936 Page 92-4. Installing The Air FilterDo not use the respirator.without the spark guardscreen, foam prefilter
POWERED AIR PURIFYING RESPIRATOROM-235 936 Page 102-5. Attaching The Connecting HoseBe sure connecting hose is.properly installed or contami-nated air
POWERED AIR PURIFYING RESPIRATOROM-235 936 Page 112-6. Operating The ControlsLeave the contami-.nated area immediate-ly if the Danger lightgoes On, t
POWERED AIR PURIFYING RESPIRATOROM-235 936 Page 122-7. Testing Air FlowAlways test air flow before.using the respirator. Alsocheck air flow each month
POWERED AIR PURIFYING RESPIRATOROM-235 936 Page 132-8. Testing Air Flow AlarmAlways test air flow alarm.before using the respirator.Also check air flo
POWERED AIR PURIFYING RESPIRATOROM-235 936 Page 142-9. Installing Shoulder Strap1 Shoulder Strap2 Snap3 LinkConnect snaps on shoulder strapsto links o
POWERED AIR PURIFYING RESPIRATOROM-235 936 Page 152-10. Checking The Respirator Before UseBefore using the respirator,check the following items:1 Air
POWERED AIR PURIFYING RESPIRATOROM-235 936 Page 162-11. Putting On The RespiratorDo not enter a hazardous.area until you are sure therespirator equipm
POWERED AIR PURIFYING RESPIRATOROM-235 936 Page 172-12. Maintenance And StorageReplace damaged or dirty air filters. Do not wash filters, clean with c
TABLE OF CONTENTSSECTION 1 − PAPR SAFETY PRECAUTIONS −READ BEFORE USING 11-1. Symbol Usage 1...
POWERED AIR PURIFYING RESPIRATOROM-235 936 Page 18Battery run time is tooshort.Replace battery.Check air filter and replace if necessary (see Sections
OM-235 936 Page 19SECTION 3 − AUTO-DARKENING HELMET See Section 2 for information on the powered air-purifying respirator (PAPR) assembly.3-1. Specif
AUTO-DARKENING HELMETOM-235 936 Page 203-2. Helmet Controls1 Reset Button (See Section3-3)2 Low Battery Indicator (See Section 3-3)3 Variable Shade C
AUTO-DARKENING HELMETOM-235 936 Page 213-3. Reset Button And Low Battery Indicator The auto-darkening lens turns on(darkens) automatically whenweldin
AUTO-DARKENING HELMETOM-235 936 Page 223-5. Variable Shade Control (No. 8 − 13)1 Variable Shade Control(No. 8 − 13)Use the control to adjust the lenss
AUTO-DARKENING HELMETOM-235 936 Page 233-6. Sensitivity Control1 Sensitivity ControlWeld ModeUse control to make the lens more respon-sive to differe
AUTO-DARKENING HELMETOM-235 936 Page 243-7. Adjusting Headgear On Standard Models There are four headgear adjust-ments: headgear top, tightness,angle
AUTO-DARKENING HELMETOM-235 936 Page 253-8. Replacing The Lens Covers On Standard Elite HelmetsRef. 804 109Never use the auto-dark-.ening lens without
AUTO-DARKENING HELMETOM-235 936 Page 263-9. Replacing Grinding Shield On Titanium 9400i HelmetRef. 804 109Never use the auto-dark-.ening lens without
AUTO-DARKENING HELMETOM-235 936 Page 273-10. Replacing The BatteryTo replace the batteries, removethe auto-darkening lensassembly (see Section 3-8).1
OM-235 936 Page 1SECTION 1 − PAPR SAFETY PRECAUTIONS −READ BEFORE USINGPAPR 2010−03Protect yourself and others from injury — read and follow these pre
AUTO-DARKENING HELMETOM-235 936 Page 283-11. Installing Optional Magnifying Lens1 Optional Magnifying LensStarting at the bottom, slide magni-fying le
AUTO-DARKENING HELMETOM-235 936 Page 293-13. TroubleshootingTrouble RemedyAuto lens not ON – auto-lens will not darken mo-mentarily when the Resetbutt
OM-235 936 Page 30SECTION 4 − PARTS LIST805 193 / Ref. 805 06812345678910111213141516181920212223242526172827Figure 4-1. Powered Air Purifying Respira
OM-235 936 Page 31DescriptionPartNo.ItemNo. QuantityFigure 4-1. Powered Air Purifying Respirator (PAPR)w/Standard Elite Helmet1 235671 PAPR (Complete
OM-235 936 Page 32805 193 / Ref. 805 068 / Ref. 804 111 / 242 3851251415161719202122232425262718678910121334292811Figure 4-2. Powered Air Purifying Re
OM-235 936 Page 33DescriptionPartNo.ItemNo. QuantityFigure 4-2. Powered Air Purifying Respirator (PAPR) w/Titanium9400i Helmet1 247531 PAPR (Complete
OM-235 936 Page 2SECTION 5 − LIMITED WARRANTYLIMITED WARRANTY – Subject to the terms and conditions below. MillerElectric Mfg. Co., Appleton, Wisconsi
OM-235 936 Page 2Noise from some processes or equipment can damage hearing. Wear approved ear protection if noise level is high.NOISE can damage h
ORIGINAL INSTRUCTIONS − PRINTED IN USA © 2011 Miller Electric Mfg. Co.Visit our website atwww.MillerWelds.com®Miller Electric Mfg. Co.An Illinois Tool
OM-235 936 Page 3RESPIRATOR (PAPR) MISUSE can be hazardous.Welding produces fumes and gases. Breathing these fumes and gases can be haz-ardous to your
OM-235 936 Page 41-3. NIOSH Approval InformationFLOW METER(ELITE)ALTERNATEHELMETASSEMBLIESALTERNATEHOSEASSEMBLIESACCESSORIESBELTEXTENSIONPARTNUMBERSHO
OM-235 936 Page 51-4. Proposition 65 WarningsWelding or cutting equipment produces fumes or gases which contain chemicals knownto the State of Califor
OM-235 936 Page 6SECTION 2 − POWERED AIR-PURIFYING RESPIRATOR(PAPR)This equipment helps protect the user from certain contaminants. All users must rea
POWERED AIR PURIFYING RESPIRATOROM-235 936 Page 72-2. Charging The BatteryCharge battery only with.supplied charger in an open,well−ventilated locatio