Engine Drive Compatibility
Control Panel
Rated Output
40 A at 140 VDC,
50% duty cycle
Max. Open-
Circuit Voltage
400 VDC
System Weight
With 12 ft (3.7 m) Torch
Net: 21 lb (9.5 kg)
Ship: 37 lb (17.5 kg)
With 20 ft (6.1 m) Torch
Net: 23 lb (10.5 kg)
Ship: 40 lb (18 kg)
Amps Input at Rated Output, 50/60 Hz, 1-Phase
208 V 230 V KVA KW
33 30 6.8 6.6
Specifications (Subject to change without notice.)
Dimensions
H: 9 in (229 mm)
W: 5-1/2 in (140 mm)
D: 13-1/4 in (337 mm)
Plasma
Gas
Air or
Nitrogen
only
Mild Steel Cutting Capability (Thickness to scale.)
Note: Recommended maximum piercing capacity for hand-held applications is 5/16 in (7.9 mm).
Maximum Sever cut of 7/8 in (22.2 mm) at 5 IPM
For aluminum and other metals with high thermal conductivity, cutting capacities may be reduced as much as 30%.
5/8 in (15.9 mm) at 12 IPM
Rated cut capacity is based on traveling approximately 12 inches per minute to achieve a steady, precise
cut. This is the key rating that should meet or exceed your typical cutting thickness requirements.
1/4 in (6.4 mm) at 60 IPM
Rated
Rated
Equipment Generator Power Steel Quality Cut (Approximate) Spectrum Output Amp Setting
Bobcat
250, Trailblazer
®
302 & 275 DC 11 kW 5/8 in 40 A, 240 V, full KVA plug
Bobcat
225 10.5 kW 5/8 in 40 A, 240 V, full KVA plug
PipePro
®
304, PRO 300 12 kW 5/8 in 40 A, 240 V, full KVA plug
Big 40
®
CC/CV Deluxe Model 12 kW 5/8 in 40 A, 240 V, full KVA plug*
Big Blue
®
500 CC/CV Deluxe Model 12 kW 5/8 in 40 A, 240 V, full KVA plug*
2
1
20
40
DC Plasma Cutting System
35
30
25
Mild Steel Recommended Cut Speeds
*
Travel speeds are approximately 80% of maximum.
Thickness Approximate Travel Speeds*
1/8 (3.2 mm) 149 IPM (3785 mm/min)
1/4 in (6.4 mm) 60 IPM (1524 mm/min)
3/8 in (9.5 mm) 34 IPM (864 mm/min)
1/2 in (12.7 mm) 21 IPM (533 mm/min)
5/8 in (15.9 mm) 12 IPM (305 mm/min)
1. Status and Troubleshooting Lights
2. Output Control
*Must derate if on standard models with only 5.5 kw peak.